Home About us Editorial board Search Ahead of print Current issue Archives Submit article Instructions Subscribe Contacts Login 
ORIGINAL ARTICLE
Year : 2022  |  Volume : 35  |  Issue : 1  |  Page : 164-171

Diagnostic accuracy of nerve conduction studies versus ultrasonography in early diagnosis of ulnar nerve entrapment at the elbow


1 Department of Physical Medicine, Rheumatology and Rehabilitation, Faculty of Medicine, Menoufia University, Menoufia, Egypt
2 Department of Radiodiagnosis, Faculty of Medicine, Menoufia University, Menoufia, Egypt

Correspondence Address:
Fatma El-Zahraa M. M. Khattab
Tala, Menoufia 32611
Egypt
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/mmj.mmj_92_21

Rights and Permissions

Background Ulnar nerve entrapment at the elbow (UNE) is a compression of the ulnar nerve at the elbow level that is mainly diagnosed clinically and confirmed by electrodiagnostic testing as well as diagnostic imaging of the ulnar nerve. Objectives To evaluate the diagnostic accuracy of nerve conduction studies (NCSs) versus ultrasonography (US) in the early diagnosis of UNE. Patients and methods This cross-sectional study included 160 patients: 80 patients with symptoms suggestive of UNE for less than or equal to 6 weeks and a control group of 80 healthy adults. Both groups were clinically examined and assessed using a self-administered questionnaire of UNE. Furthermore, motor and sensory NCS and short-segment nerve conductions of ulnar nerve in both groups with measurement of ulnar nerve cross-sectional area using US in the case group were performed. Results A high sensitivity of using NCSs for early diagnosis of UNE measuring conduction velocity and amplitude was exhibited via traditional 10-cm NCSs (95 and 82.5%, respectively) and short-segment nerve conductions (97.5 and 90%, respectively). US has showed a decrease in the sensitivity (40%) in comparison with short-segment amplitude drop, with an accuracy of 91% as well as a specificity of 99%, and there was a high sensitivity of short-segment amplitude drop D2/ME (80%) when compared with US at P2, which exhibited an accuracy of 91% and specificity of 92%. Conclusion Herein, electrodiagnostic in addition to the US studies would play a vital role in increasing the accuracy of diagnosis of UNE; additionally, it will help in precise localization of the site of pathology.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed666    
    Printed16    
    Emailed0    
    PDF Downloaded70    
    Comments [Add]    

Recommend this journal