Home About us Editorial board Search Ahead of print Current issue Archives Submit article Instructions Subscribe Contacts Login 
ORIGINAL ARTICLE
Year : 2016  |  Volume : 29  |  Issue : 2  |  Page : 423-430

Diagnostic impact of serum myoglobin and human heart-type fatty acid binding protein in patients with acute myocardial infarction


1 Department of Cardiology, Faculty of Medicine, Menoufia University, Menoufia, Egypt
2 Department of Medical Biochemistry, Faculty of Medicine, Menoufia University, Menoufia, Egypt

Correspondence Address:
Emtiaz F Amin El-Lakwah
Nasr City, Cairo, 11371
Egypt
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/1110-2098.192446

Rights and Permissions

Objective: The aim of the study was to assess the value of the serum concentrations of myoglobin and human heart-type fatty acid binding protein (H-FABP) in the early detection of acute myocardial infarction (AMI). Background: Myoglobin and H-FABP are useful as biochemical markers of muscle injury. We conducted this investigation to detect whether both markers and their ratio were useful in the early detection of AMI. Patients and methods: This study included 21 patients with AMI, 20 patients with skeletal muscle injury, and 10 normal healthy individuals. Their blood samples were obtained (within 6 h of onset of chest pain in AMI patients), and serum concentrations of creatinine, aspartate aminotransferase, H-FABP, myoglobin, cardiac troponin I, and creatine kinase-MB (CK-MB) were determined. Results: It was found that H-FABP has higher sensitivity and predictive accuracy compared with myoglobin in the early detection of AMI: the sensitivity of H-FABP was 95% and that of myoglobin was 81%, and the sensitivity of their ratio was 90%. H-FABP is a more sensitive marker, but in our study its specificity was 90%, which was lower than that of myoglobin (99%) for the detection of AMI within 6 h after the onset of chest pain. Also, our study showed that myoglobin and H-FABP were directly proportional to troponin and CK-MB, in which there is significant positive correlation. Conclusion: The diagnostic sensitivity of H-FABP is high, above that of myoglobin in patients presenting within 6 h of chest pain. H-FABP is a sensitive and specific marker for the early diagnosis of AMI. The lower specificity of H-FABP makes troponin and CK-MB superior for the diagnosis of AMI.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed2595    
    Printed173    
    Emailed0    
    PDF Downloaded162    
    Comments [Add]    

Recommend this journal