Home About us Editorial board Search Ahead of print Current issue Archives Submit article Instructions Subscribe Contacts Login 
ORIGINAL ARTICLE
Year : 2017  |  Volume : 30  |  Issue : 2  |  Page : 485-491

Intraocular lens master optical biometry versusconventionalultrasound biometry in intraocular lens power calculations in highly myopic eyes


1 Department of Ophthalmology, Menoufia University, Menoufia, Egypt
2 Department of Biochemistry, Menoufia University, Menoufia, Egypt
3 Department of Ophthalmology, Ministry of Health, KalawounEyeHospital, Cairo, Egypt

Correspondence Address:
Mohammed A Fouad
Faysal, Giza, 22511
Egypt
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/1110-2098.215434

Rights and Permissions

Objective The aim of this study wastocompare the accuracy of optical biometry and applanation ultrasound measurement of the preoperative intraocular lens(IOL) power calculation formulas(Haigis, SRK/T, and Hoffer Q) of highly myopic eye. Background Implantation of an IOL is the cornerstone in modern day cataract surgery, which is no longer used for just visual rehabilitation but has also become a form of refractive surgery in which the final refractive result can define visual outcome. Accurate biometry necessitates proper axial lens measurements. Patients and methods This study included 60 eyes of 52patients(nine cases of bilateral and 42cases of unilateral cataract)[27female(45%) and 33male(55%)] with extreme myopia and axial lengths longer than 26.0mm with cataract as the only ocular pathology. Patients were divided into two groups. Group1(the optical biometry group) included 30patients and group2(the A-scan ultrasound group) included 30patients. Eyeswith significant cataract suitable for phacoemulsification and primary in-bag implantation of posterior chamber IOL were included. All patients underwent clear corneal phacoemulsification by the same surgeon and implantation of the one-piece soft hydrophobic acrylic IOL(EYECRYL-600L) IOL(power range−5.0.0 to+15.0 D). Results This study was carried out on 60 eyes of 52 highly myopic patients presenting with cataract. Patients were divided into two groups: group1, which included 30 eyes that underwent optical biometry using Zeiss 5000 IOL Master, and group2, which included 30 eyes that underwent A-scan ultrasound biometry using Sonomed PAC SCAN 300 AP. Conclusion Haigis formula with the Zeiss IOL Master using partial coherence interferometry gives significantly better IOL power prediction in highly myopic eyes with cataract compared with US biometry.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed446    
    Printed1    
    Emailed0    
    PDF Downloaded53    
    Comments [Add]    
    Cited by others 1    

Recommend this journal