Home About us Editorial board Search Ahead of print Current issue Archives Submit article Instructions Subscribe Contacts Login 
ORIGINAL ARTICLE
Year : 2017  |  Volume : 30  |  Issue : 2  |  Page : 425-433

Evaluation of hook plate for fixation of displaced lateral third fractures of the clavicle


Department of Orthopedics Surgery, Faculty of Medicine, Menoufia University, Shebien El-Kom, Egypt

Correspondence Address:
Adham E Mousa
8 Rashad El Tabl Street, El Bar El Sharky, Shebien El-Kom, Menoufia Governorate, 32111-13
Egypt
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/1110-2098.215439

Rights and Permissions

Objectives The aim of this study was to assess the effectiveness of open reduction and internal fixation of Neer typeII unstable lateral third clavicle fractures using the clavicle hook plate(HP). Background In the last decade, the clavicle HP has been in use. Reports about this plate have showed a high success rate in terms of union. However, there is still concern as regards rate of mid-term complications, particularly the involvement of the acromioclavicular joint(ACJ). Patients and methods To evaluate the results and mid-term effects in use of this plate, we performed a prospective analysis with a mean follow-up of 17months(1.45years) of 20 consecutive patients with acute displaced lateral clavicle fractures, treated with the clavicle HP. Results Short-term functional results in all patients were good to excellent. All but one (95%) patient had a united fracture. Five (25%) patients developed impingement symptoms, and in two (10%) patients fsubacromial osteolysis was found. These findings resolved after plate removal. Twenty patients were evaluated at a fixed initial follow-up visit, 3months postoperatively, and re-evaluated at a mean follow-up period of 1.45years. The final Constant Shoulder score mean was 95.5 and the disabilities of the arm, shoulder and hand score (DASH) mean was 3.54 preoperatively compared with 92.9 and 4.26, respectively, before plate removal (P=0.000). One(5%) patient developed ACJ arthrosis, which was symptomatic. Two (10%) patients had extra-articular ossifications, of which one was symptomatic. There was no relation between the impingement symptoms, subacromial osteolysis, and development of ACJ arthrosis or extra-articular ossifications. Conclusion The clavicle HP is a good primary treatment option for acute displaced lateral clavicle fracture with few complications. At mid-term, the results are excellent, and no long-term complications can be attributed to the use of the plate.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed600    
    Printed0    
    Emailed0    
    PDF Downloaded112    
    Comments [Add]    

Recommend this journal